Safe Box L | XL安全监控,用于电梯

    读值电子元件,实施与安全有关的开关和控制功能
    多达4对安全继电器
    ETSL延时控制、末端位置、门区、安全制动释放
    开关和安全功能在适配和扩展时具有灵活性
    多达29个安全输入、9个输出
    2个安全电路输入(110 V、220 VAC或48 VDC)
    CAN接口DS406用于参数设置或电梯轿厢位置传输
    客户指定的软件可以在准备阶段进行使用

Produktanfrage

MECHANICAL DATA

Housing material aluminium
Housing dimensions
(W x B x H)
Safe Box L: 220 x 134 x 97 mm, Safe Box XL: 220 x 134 x 134 mm
Signal cable (SCA and PIO) 1.5 m standard length
Connections sensor: pluggable M12 socket, SCA, PIO cable: open cable ends, optional with plug connectors
Weight Safe Box L: approx. 1640 g (without cable), Safe Box XL: approx. 1800 g (without cable), cable: approx. 60 g/m

 ELECTRICAL DATA

Power supply voltage 24 VDC, +20% / -25%
Residual ripple < 100 mV
Current consumption Safe Box L: max. 500 mA, Safe Box XL: max. 750 mA
Battery voltage 12 VDC ± 20%
Interfaces CANopen - DS406, others on request, RS485 for sensor communication
Number of safe inputs Safa Box L: 7, Safe Box XL: 21 + 8
Number of safety circuit inputs 2 (110 V, 220 VAC or 48 VDC)
Number of electronic outputs Safe Box L: 1, Safe Box XL: max. 9

SAFETY RELAYS

Number of safety relays standard: 3 (OC, NOC, SGC), optional 4
Voltage 110 VAC / 220 VAC / 24 VDC
Contact load  standard: max. 2 A, optional: max. 4 A
Response time < 55 ms

 CONFORMANCE / STANDARDS / CERTIFICATIONS

Achieved SIL  SIL3 (in preparation)
Fulfilled standards EN81-20 (in perparation)
Further certifications EC type-examination (in perparation)

 

ENVIRONMENTAL CONDITIONS

Storage temperature -25 ... +85 °C 
Operating temperature -10 ... +70 °C, -25 ... +85 °C on request
Humiditiy 95 %, non-condensing
Operating height max. 2000 m above sea level
Protection class IP54 (according to EN60529), higher on request
Interference emission/ immunity  EN 12015 / EN 12016
Vibration/ shock resistance EN 60068-2-6 / EN 60068-2-27 / EN 60068-2-29
Delay by motor brake > 1.7 m/s²
Delay by lift control < 1.2 m/s²
Buffer dimensioning > 0.63 m/s² (inspection speed)